Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/16291
Title: Assessment of Normal force testing to measure adhesion at organic-inorganic interfaces in organic optoelectronic devices
Authors: Das Gupta, Hrishikesh
Advisor: Tutak, Dr. Ayse
Department: Engineering Physics
Keywords: Organic optoelectronic device;Adhesion;Normal testing system;organic-inorganic interface
Publication Date: Nov-2014
Abstract: Organic photovoltaic (OPV) devices are emerging as a reliable source of energy due to their combination of unique features. Though desired for their flexibility, low cost, light weight, large area fabrication compatibility and eco-friendly nature, these devices face numerous challenges in achieving high performance and stability. The organic-electrode interface specifically plays a key role in controlling device stability. Recent studies have revealed that the stability is heavily affected by the adhesion of the organic-electrode interface. Measurement of adhesion at these interfaces, however, is a challenging task. In this study, Normal Force Adhesion testing was assessed to determine its suitability for organic devices. In this approach, force is applied perpendicular to the substrate, over the entire surface area of one device (9 mm2) until delamination occurs. In addition to the extracted force-distance curves, images of the interfaces before and after each experiment and a real-time, in-situ video taken from a lateral perspective were examined. All three of these critical pieces of information are necessary to obtain a complete picture of the success of a Normal test. A statistical assessment has been made of the testing apparatus, using many samples (> 50) of one metal - organic combination, Al-Alq3 - an archetypal combination for organic electronics. In addition, five other metal-organic combinations widely used in organic electronic devices, have been chosen to assess the Normal force approach. Due to the ease of testing a large number of samples, Normal force testing does appear to be a viable approach to examining interfacial adhesion, though care must be taken in the experimental design to avoid common experimental failures. Based on the results, a few recommendations have been made to improve the utility of the adhesion testing system for rapid quality testing of organic devices.
URI: http://hdl.handle.net/11375/16291
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Assessment of Normal force testing to measure adhesion at organic-inorganic interfaces in organic optoelectronic devices.pdf
Access is allowed from: 2015-09-19
Introduction and motivation, Adhesion theory, Material systems, Experimental procedure, Result and analysis, Conclusion92.24 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue