Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Electrical and Computer Engineering
  5. EE 4BI6 Electrical Engineering Biomedical Capstones
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14474
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSingh, Kalsi Mastanen_US
dc.date.accessioned2014-06-18T18:13:25Z-
dc.date.available2014-06-18T18:13:25Z-
dc.date.created2009-09-17en_US
dc.date.issued2009-04-23en_US
dc.identifier.otheree4bi6/7en_US
dc.identifier.other1006en_US
dc.identifier.other1008543en_US
dc.identifier.urihttp://hdl.handle.net/11375/14474-
dc.description.abstract<p>An infrared emitter and a photodiode pressed against a highly vascular surface of a finger or on the brachial artery allow the photodiode to generate a current based on the infrared light it receives. Moreover, the varying amount of blood in the artery as the pulse passes through it impacts the light intensity the photodiode receives. Therefore, the signal received from the photodiode can be used to calculate the instantaneous heart rate and consequently the heart rate variability. Furthermore, the signal received from the photodiode is the photoplethysmographic (PPG) waveform which can be used to calculate the pulse transit time (PTT), the pulse height, and the breathing rate. PTT is the time interval between a peak on the finger PPG waveform and the corresponding peak on the brachial artery PPG waveform. Since PTT is inversely related to blood pressure changes, and the pulse height is proportional to the difference between the systolic and the diastolic pressure in the arteries, with correlation coefficients calculated with the aid of a standard blood pressure monitoring system, arterial blood pressure values can be calculated. By comparing the theories encompassing the hardware design with the experimental results the report articulates the effectiveness of the device.</p>en_US
dc.subjectarterial blood pressureen_US
dc.subjectbrachial arteryen_US
dc.subjectbreathing rateen_US
dc.subjectheart rate variabilityen_US
dc.subjectphotodiodeen_US
dc.subjectphotoplethysmographicen_US
dc.subjectPPGen_US
dc.subjectPTTen_US
dc.subjectpulse heighten_US
dc.subjectsystolic and diastolic pressureen_US
dc.subjectBiomedicalen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectBiomedicalen_US
dc.titleDesign of Arterial Blood Pressure, Heart Rate Variability, and Breathing Rate Monitoring Deviceen_US
dc.typecapstoneen_US
Appears in Collections:EE 4BI6 Electrical Engineering Biomedical Capstones

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
915.03 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue