Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Electrical and Computer Engineering
  5. EE 4BI6 Electrical Engineering Biomedical Capstones
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14457
Full metadata record
DC FieldValueLanguage
dc.contributor.authorArabi, Mohammad N.en_US
dc.date.accessioned2014-06-18T18:13:23Z-
dc.date.available2014-06-18T18:13:23Z-
dc.date.created2011-02-18en_US
dc.date.issued2010-03-15en_US
dc.identifier.otheree4bi6/54en_US
dc.identifier.other1039en_US
dc.identifier.other1796637en_US
dc.identifier.urihttp://hdl.handle.net/11375/14457-
dc.description.abstract<p>The percentage of arterial oxygen in the blood is a vital physiological sign used by clinicians and doctors to monitor the health of patients under critical conditions in the hospital; the technology used universally to monitor this is known as pulse oximetry. The sensors most commonly used in the hospitals are of reflection type such that the LEDs and the photodetector (PD) are placed on opposite ends of short distance body tissue, e.g. finger. There has been an increased demand for monitoring patients who have suffered a stroke and are recovering in their homes, and simply the elderly. For such persons, staying in the hospital is unnecessary and undesirable psychologically. As such, a system is to be designed such that patients can monitor their physiological signals, and only contact the doctor when it is imperative to do so. With the comfort of the patient in mind, the system must be unobtrusive in nature such that it does not impede any of their simply daily activities. The sensor used in the system is of reflectance type, i.e. LEDs and PD placed on the same side, and is to be placed on the pectoral region. The pectoral region is chosen for the ease of measuring electrocardiogram (ECG) signals, another vital physiological signal. Due to lesser blood perfusion in that anatomical region, the question remains as to whether signals could be acquired faithfully there. Results have shown that although signals can be obtained, they vary greatly mainly due to motion artifacts. The system could be improved if complex digital signal processing algorithms are used.</p>en_US
dc.subjectPulse Oximetryen_US
dc.subjectReflectance Sensoren_US
dc.subjectMotion Artifactsen_US
dc.subjectWirelessen_US
dc.subjectAutomatic Gain Controlen_US
dc.subjectBiomedicalen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectBiomedicalen_US
dc.titleTowards a Non-Intrusive Pulse Oximetry System with Long-Term Mobile Monitoringen_US
dc.typecapstoneen_US
Appears in Collections:EE 4BI6 Electrical Engineering Biomedical Capstones

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
1.75 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue