Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Electrical and Computer Engineering
  5. EE 4BI6 Electrical Engineering Biomedical Capstones
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14442
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSia, Dinoen_US
dc.date.accessioned2014-06-18T18:13:19Z-
dc.date.available2014-06-18T18:13:19Z-
dc.date.created2011-02-18en_US
dc.date.issued2010-04en_US
dc.identifier.otheree4bi6/40en_US
dc.identifier.other1053en_US
dc.identifier.other1796981en_US
dc.identifier.urihttp://hdl.handle.net/11375/14442-
dc.description.abstract<p>Maintaining healthy blood glucose concentration levels is advantageous for the prevention of diabetes and obesity. Present day technologies limit such monitoring to patients who already have diabetes. The purpose of this project is to suggest a non-invasive method for measuring blood glucose concentration levels. Such a method would provide useful for even people without illness, addressing preventive care. This project implements near-infrared light of wavelengths 1450nm and 2050nm through the use of light emitting diodes and measures transmittance through solutions of distilled water and d-glucose of concentrations 50mg/dL, 100mg/dL, 150mg/dL, and 200mg/dL by using an InGaAs photodiode. Regression analysis is done. Transmittance results were observed when using near-infrared light of wavelength 1450nm. As glucose concentration increases, output voltage from the photodiode also increases. The relation observed was linear. No significant transmittance results were obtained with the use of 2050nm infrared light due to high absorbance and low power. The use of 1450nm infrared light provides a means of measuring glucose concentration levels.</p>en_US
dc.subjectLight emitting diodeen_US
dc.subjectglucoseen_US
dc.subjectblooden_US
dc.subjectphotodiodeen_US
dc.subjectphotodetectoren_US
dc.subjecttransmittanceen_US
dc.subjectspectroscopyen_US
dc.subjectBiomedicalen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectBiomedicalen_US
dc.titleDesign of a Near-Infrared Device for the Study of Glucose Concentration Measurementsen_US
dc.typecapstoneen_US
Appears in Collections:EE 4BI6 Electrical Engineering Biomedical Capstones

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
835.77 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue