Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Electrical and Computer Engineering
  5. EE 4BI6 Electrical Engineering Biomedical Capstones
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14412
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMcNabb, Evanen_US
dc.date.accessioned2014-06-18T18:13:12Z-
dc.date.available2014-06-18T18:13:12Z-
dc.date.created2009-09-17en_US
dc.date.issued2009-04-27en_US
dc.identifier.otheree4bi6/11en_US
dc.identifier.other1010en_US
dc.identifier.other1008556en_US
dc.identifier.urihttp://hdl.handle.net/11375/14412-
dc.description.abstract<p>The use of a bionic hand using a non invasive interface is a project aimed at restoring motor function and limited sensory information to a patient who has lost a hand or an arm. The use of an easy to use interface that gives the user control with their functioning hand simplifies daily activities that would otherwise be more difficult. Signal extraction can be acquired from the control unit using magnetic Hall Effect sensors which then act as a 2-bit binary positional system for the output of the bionic hand. Electronic circuitry must be developed to safely transmit control signals to hardware and also send appropriate output pulses to drive the mechanical system. In addition a microcontroller must be programmed for the logical control of the output with respect to the control signals and feedback from pressure sensors on the bionic hand. Important theoretical developments are discussed with a design strategy on implementing the solution. Input regulation is developed to isolate the control signals from the microcontroller to protect the user and the equipment of any possible damage. Logical programming is done on the microcontroller via C to receive inputs and act as a 2-to-4 decoder for output paths, with appropriate output pulses to the motors. In addition the programming is able to receive feedback from the hand in the form or pressure sensors that alert the user when objects are grasped and firmly held. This report concludes with a critical analysis of the results obtained and future recommendations on delivering a more accurate project.</p>en_US
dc.subjectBionicen_US
dc.subjectnon-invasive human-computer interfaceen_US
dc.subjectHall Effecten_US
dc.subjectpressure feedbacken_US
dc.subjectmotor controlen_US
dc.subjectprogrammingen_US
dc.subjectmicrocontroller.en_US
dc.subjectBiomedicalen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectBiomedicalen_US
dc.titleDesign of a Bionic Hand Using Non Invasive Interfaceen_US
dc.typecapstoneen_US
Appears in Collections:EE 4BI6 Electrical Engineering Biomedical Capstones

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
761.11 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue