Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/13778
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorTrojan, O.A.en_US
dc.contributor.authorAttia, A.en_US
dc.date.accessioned2014-06-18T17:05:13Z-
dc.date.available2014-06-18T17:05:13Z-
dc.date.created2013-12-09en_US
dc.date.issued1973en_US
dc.identifier.otheropendissertations/8605en_US
dc.identifier.other9686en_US
dc.identifier.other4899926en_US
dc.identifier.urihttp://hdl.handle.net/11375/13778-
dc.description.abstract<p>In the design of nuclear reactor cores, as elsewhere, it is important to know the accuracy of the analytical tools (computer codes) which are used. An accurate and effective way of obtaining this knowledge is to compare, for controlled reactor conditions, the measured with the simulated neutron flux distributions. The results of the SORGHUM code, which is used for evaluating methods of controlling large power reactors during and after some prescribed perturbations, were checked by simulating the reactor conditions existing in Pickering Reactor Unit 2 for the wire activation experiments during low power Phase B commissioning. Thermal flux distributions were measured for 13 different configurations of the reactivity control devices of Pickering reactor in two fuel channels Ml2 and K5. The SORGHUM code was used to simulate the conditions in 11 of the 13 experiments. The reactivity devices were represented rather simply by an incremental thermal absorption cross-section only. Some slight adjustment to these cross-sections was found necessary to obtain agreement with experimental results for both channels within a maximum discrepancy of 10%. A reactivity worth was calculated of 20.5 mk for alI adjuster rods and 5.0 mk for zone controllers. This should be compared with the measured values of 20.0 mk and 5.0 mk for adjuster rods and zone controllers, respectively.</p>en_US
dc.subjectnuclear reactor coresen_US
dc.subjectdesignen_US
dc.subjectthermal fluxen_US
dc.subjectSORGHUM codeen_US
dc.subjectEngineeringen_US
dc.subjectNuclear Engineeringen_US
dc.subjectEngineeringen_US
dc.titleSimulation of Wire Activation Experiments of Pickering Reactor Unit Number 2 Part A: Industrial Project Bipolar Junction Phototransistor Modelling Part B: McMaster (On-Campus) Projecten_US
dc.typethesisen_US
dc.contributor.departmentEngineering Physicsen_US
dc.description.degreeMaster of Engineering (MEngr)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
2.74 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue