Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/13529
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSelvaganapathy, P.R.en_US
dc.contributor.advisorChing, C.Y.en_US
dc.contributor.advisorKoshy, Philen_US
dc.contributor.authorZHU, CHAOen_US
dc.date.accessioned2014-06-18T17:04:19Z-
dc.date.available2014-06-18T17:04:19Z-
dc.date.created2013-09-25en_US
dc.date.issued2013-10en_US
dc.identifier.otheropendissertations/8365en_US
dc.identifier.other9428en_US
dc.identifier.other4626969en_US
dc.identifier.urihttp://hdl.handle.net/11375/13529-
dc.description.abstract<p>Microdroplets find use in a variety of applications ranging from chemical synthesis to biological analysis. However, commercial use of microdroplets has been stymied in many applications, as current devices lack one or more of the critical features such as precise and dynamic control of the droplet size, high throughput and easy fabrication. This work involves design, fabrication and characterization of a microdroplet generating device that uses low cost fabrication, allows dynamic control of the droplet size and achieves parallelized droplet generation for high throughput.</p> <p>Dynamic droplet size control by DC electric field has been demonstrated with the device. By varying the potential from 300 V to 1000 V, the droplet size can change from 140 microns to around 40 microns . The transition of the droplet size just takes few seconds. Parallelized droplet generation has also been demonstrated. The standard deviation of the droplet size is lower than 4% for the three-capillary device and lower than 6% for the five-capillary device under different operating conditions. Highest throughput of 0.75 mL/hour is achieved on the five-capillary device. It has been show that this proposed device has a better performance than the existing PDMS based parallel droplet generating devices. A theoretical model of the droplet generating process has also been developed which is able to predict the droplet size at various potentials. The theoretical results are in good agreement with experimental ones.</p>en_US
dc.subjectMicrofluidicsen_US
dc.subjectDroplet Generationen_US
dc.subjectElectrically Controlen_US
dc.subjectParallelizationen_US
dc.subjectOther Mechanical Engineeringen_US
dc.subjectOther Mechanical Engineeringen_US
dc.titleDesign and Analysis of A Parallelized Electrically Controlled Droplet Generating Deviceen_US
dc.typethesisen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
1.98 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue