Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/13100
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorThompson, D.A.en_US
dc.contributor.authorAkano, Gbadebo Usmanen_US
dc.date.accessioned2014-06-18T17:02:28Z-
dc.date.available2014-06-18T17:02:28Z-
dc.date.created2013-07-16en_US
dc.date.issued1980en_US
dc.identifier.otheropendissertations/7929en_US
dc.identifier.other8999en_US
dc.identifier.other4320757en_US
dc.identifier.urihttp://hdl.handle.net/11375/13100-
dc.description.abstract<p>The project is concerned with development of suitable anode electrodes for oxygen evolution in 30 w/o KOH solution at BO°C. Li ions (15 keV, 40 keV and 60 keV) at doses of 1 x 10<sup>15</sup> to 1.5 x 10<sup>16</sup> ions/cm<sup>2</sup>, He ions (15 keV, 40 keV) at 3 x 10<sup>15</sup> ions/cm<sup>2</sup> and Ag ion (50 keV) at 1 x 10<sup>16</sup> to 4 x 10<sup>16</sup> ions/cm<sup>2</sup> have been implanted into polycrystalline Ni and oxidized Ni at room temperature. Ag has also been recoil implanted into Ni and NiO. Current-potential measurements have been carried out using galvanostatic techniques with the implanted samples as the oxygen electrode in 30 w/o KOH solution at BO°C. The Ag-imp1anted electrodes show a substantial reduction in electrode potential at 1 A/cm<sup>2</sup> (~ 60% compared to polished Ni) and all implanted samples show a more uniform corrosion products on the surface. Dual Tafel slopes are observed for all electrodes and the higher slope at the higher current densities is thought to be due to the formation of nickel oxide on the electrodes. The Tafel slope and exchange current density, at low current densities are considered consistent with reported data. RBS analysis of the Ag-imp1anted electrodes indicates that no Ag is lost as a result of the electrochemical measurements.</p>en_US
dc.subjectEngineering Physicsen_US
dc.subjectEngineering Physicsen_US
dc.titleApplication of Ion Implantation Techniques to Anode Electrocatalyst Development for Use in Alkaline Water Electrolysisen_US
dc.typethesisen_US
dc.contributor.departmentEngineering Physicsen_US
dc.description.degreeMaster of Engineering (ME)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
34.85 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue