Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/12682
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorNikolova, Nataliaen_US
dc.contributor.advisorNoseworthy, Michaelen_US
dc.contributor.advisorFang, Qiyinen_US
dc.contributor.authorBaskharoun, Yonaen_US
dc.date.accessioned2014-06-18T17:00:21Z-
dc.date.available2014-06-18T17:00:21Z-
dc.date.created2012-09-25en_US
dc.date.issued2012-10en_US
dc.identifier.otheropendissertations/7547en_US
dc.identifier.other8538en_US
dc.identifier.other3349947en_US
dc.identifier.urihttp://hdl.handle.net/11375/12682-
dc.description.abstract<p>Accurate knowledge of the frequency- and temperature-dependent dielectric properties of biological tissues is crucial in the development of ultra-wideband diagnostic and therapeutic technologies such as microwave breast cancer detection and hyperthermia treatments. This work examines the temperature dependence of the dielectric properties of the five tissue phantom-types developed by our group as well as porcine fat, muscle and liver tissues for the frequency range from 3 GHz to 10 GHz and for the temperature range from 5 °C to 45 °C. A systematic and simple measurement procedure is developed to measure the continuous temperature dependence of the dielectric properties of the various phantom and tissue types. The temperature trends of the dielectric properties of the different phantoms and tissues are investigated.</p> <p>Linear temperature coefficients at discrete frequencies are impractical and insufficient in ultra-wideband applications when realistic, non-linear numerical models of the dielectric properties are required. Therefore, a compact one-pole Cole-Cole model is used to model the frequency dependence of the dielectric properties of the measured samples at every temperature point. A second- or third-order polynomial is used to model the temperature dependence of the Cole-Cole parameters. The final model is a one-pole Cole-Cole model whose parameters are polynomial functions of temperature. This model enables the estimation of the relative permittivity and the conductivity of the measured phantom and tissue types at any temperature and frequency.</p>en_US
dc.subjectTissue Propertiesen_US
dc.subjectDielectric Propertiesen_US
dc.subjectMicrowave Imagingen_US
dc.subjectBreast Imagingen_US
dc.subjectTemperature Dependenceen_US
dc.subjectCole-Cole Modelen_US
dc.subjectBiomedicalen_US
dc.subjectBiomedicalen_US
dc.titleTemperature-Dependent Dielectric Properties of Tissue Phantoms and Tissue Samples at Microwave Frequenciesen_US
dc.typethesisen_US
dc.contributor.departmentElectrical and Computer Engineeringen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
76.77 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue