Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/12526
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSelvaganapathy, Ravi P.en_US
dc.contributor.authorIslam, Md. Shehadulen_US
dc.date.accessioned2014-06-18T16:59:56Z-
dc.date.available2014-06-18T16:59:56Z-
dc.date.created2012-09-21en_US
dc.date.issued2012-10en_US
dc.identifier.otheropendissertations/7405en_US
dc.identifier.other8462en_US
dc.identifier.other3340606en_US
dc.identifier.urihttp://hdl.handle.net/11375/12526-
dc.description.abstract<p>Microbiological contamination from bacteria such as <em>Escherichia coli</em> and Salmonella is one of the main reasons for waterborne illness. Real time and accurate monitoring of water is needed in order to alleviate this human health concern. Performing multiple and parallel analysis of biomarkers such as DNA and mRNA that targets different regions of pathogen functionality provides a complete picture of its presence and viability in the shortest possible time. These biomarkers are present inside the cell and need to be extracted for analysis and detection. Hence, lysis of these pathogenic bacteria is an important part in the sample preparation for rapid detection. In addition, collecting a small amount of bacteria present in a large volume of sample and concentrating them before lysing is important as it facilitates the downstream assay. Various techniques, categorized as mechanical, chemical, thermal and electrical, have been used for lysing cells. In the electrical method, cells are lysed by exposure to an external electric field. The advantage of this method, in contrast to other methods, is that it allows lysis without the introduction of any chemical and biological reagents and permits rapid recovery of intercellular organelles. Despite the advantages, issues such as high voltage requirement, bubble generation and Joule heating are associated with the electrical method.</p> <p>To alleviate the issues associated with electrical lysis, a new design and associated fabrication process for a microfluidic cell lysis device is described in this thesis. The device consists of a nanoporous polycarbonate (PCTE) membrane sandwiched between two PDMS microchannels with electrodes embedded at the reservoirs of the microchannels. Microcontact printing is used to attach this PCTE membrane with PDMS.</p> <p>By using this PCTE membrane, it was possible to intensify the electric field at the interface of two channels while maintaining it low in the other sections of the device. Furthermore, the device also allowed electrophoretic trapping of cells before lysis at a lower applied potential. For instance, it could trap bacteria such as <em>E. coli</em> from a continuous flow into the intersection between two channels for lower electric field (308 V/cm) and lyse the cell when electric field was increased more than 1000 V/cm into that section.</p> <p>Application of lower DC voltage with pressure driven flow alleviated adverse effect from Joule heating. Moreover, gas evolution and bubble generation was not observed during the operation of this device.</p> <p>Accumulation and lysis of bacteria were studied under a fluorescence microscope and quantified by using intensity measurement. To observe the accumulation and lysis, LIVE/DEAD BacLight Bacterial Viability Kit consisting of two separate components of SYTO 9 and propidium iodide (PI) into the cell suspension in addition to GFP expressed <em>E. coli</em> were used. Finally, plate counting was done to determine the efficiency of the device and it was observed that the device could lyse 90% of bacteria for an operation voltage of 300V within 3 min.</p> <p>In conclusion, a robust, reliable and flexible microfluidic cell lysis device was proposed and analyzed which is useful for sample pretreatment in a Micro Total Analysis System.</p>en_US
dc.subjectCell Lysisen_US
dc.subjectMicrofluidicsen_US
dc.subjectElectrical Lysisen_US
dc.subjectBacterial Lysisen_US
dc.subjectElectroporationen_US
dc.subjectPolycarbonate Membraneen_US
dc.subjectBiochemical and Biomolecular Engineeringen_US
dc.subjectBioimaging and biomedical opticsen_US
dc.subjectBiological Engineeringen_US
dc.subjectBiomedicalen_US
dc.subjectElectro-Mechanical Systemsen_US
dc.subjectMembrane Scienceen_US
dc.subjectMolecular, cellular, and tissue engineeringen_US
dc.subjectNanoscience and Nanotechnologyen_US
dc.subjectOther Mechanical Engineeringen_US
dc.subjectBiochemical and Biomolecular Engineeringen_US
dc.titleA Low Power Electrical Method for Cell Accumulation and Lysis Using Microfluidicsen_US
dc.typethesisen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
1.91 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue