Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/11163
Title: ELECTROCHEMICAL PROPERTIES OF FLEXIBLE ELECTRODES FOR IMPLANTED NEUROMUSCULAR EXCITATION APPLICATIONS
Authors: Mohtashami, Saba
Advisor: Howlader, Matiar R.
Doyle, Thomas E.
Joseph Kish, Hubert Debruin
Department: Electrical and Computer Engineering
Keywords: Electrical and Computer Engineering;Electrical and Computer Engineering
Publication Date: Oct-2011
Abstract: <p>This thesis investigates the electrochemical performance of flexible implanted electrodes for the purpose of neuromuscular electrical stimulation. Electrodes performance is validated through their conductivity, stability, and charge delivery capacity (CDC) to avoid irreversible faradaic reactions during stimulation. To study these requirements, electrodes were fabricated by depositing platinum (Pt), gold (Au) and titanium (Ti) thin films on the flexible liquid crystal polymer (LCP) substrate. Their electrochemical properties were then studied using surface and interface characterization techniques including atomic force microscopy (AFM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and a theoretical model. The EIS results demonstrate that larger electrodes provide higher conductivity and double layer capacitance. In terms of material, Pt offers the best conductivity in neuromuscular stimulation frequencies of 1- 250 Hz, followed by Ti and Au, respectively. Above 250 Hz, similar values of conductivity is offered by the electrodes. This material dependence of impedance magnitude is related to the surface morphology, structural quality and deposition parameters of the electrodes and is explained using surface roughness measurements and interface model parameters. Electrode long-term stability is explored by regular EIS measurements through 42-day experiments. With progressing time, an increase in surface roughness, decrease in chargetransfer resistance (Rct) and capacitive quality (¯) are observed due to the change in capacitive and faradaic behaviors. However, in the comparative evaluations, Au electrode shows the most consistency in keeping its capacitive behavior to perform reversible charge transfer, followed by Pt and Ti, respectively. Further, cyclic voltammetry (CV) curves were used to understand the charge transfer reactions and calculate charge delivery capacities (CDC) of Pt, Ti and Au. Pt with highest CDC value suggests the best electrochemical reversibility followed by Au and Ti. In the case of deposition pressure, for Ti electrode, lower deposition pressure yields higher charge delivery capacity. These results may make lower pressure deposited Pt electrode with high conductivity and CDC the best material for the short term applications of neuromuscular electrical stimulation, while Au possessing improved stability but lower conductivity and CDC is suggested for long term applications. This result provides deeper insight into the design and miniaturization of electrochemical electrodes for the further development of neuromuscular prostheses.</p>
URI: http://hdl.handle.net/11375/11163
Identifier: opendissertations/6152
7178
2238203
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
2.18 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue