Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/10023
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMoran, Gerald Ren_US
dc.contributor.advisorMichael Patterson, Cecile Fradinen_US
dc.contributor.advisorMichael Patterson, Cecile Fradinen_US
dc.contributor.authorSaeed, Farukhen_US
dc.date.accessioned2014-06-18T16:49:28Z-
dc.date.available2014-06-18T16:49:28Z-
dc.date.created2011-06-30en_US
dc.date.issued2011-10en_US
dc.identifier.otheropendissertations/5091en_US
dc.identifier.other6060en_US
dc.identifier.other2082228en_US
dc.identifier.urihttp://hdl.handle.net/11375/10023-
dc.description.abstract<p>This thesis is composed of six chapters. First MRE is briefly introduced together with some relevant literature in Chapter one. The second chapter is about the principles and theory of magnetic resonance imaging, with the MRE theory, software and hardware addressed in Chapter 3. Chapters 4 and 5 describe the hardware design, software programming, experimental setup and elasticity reconstruction. Chapter 6 is a general discussion, introducing challenges and future directions.</p> <p>A vibration actuator and coil was designed and constructed, then combined with the necessary hardware required to induce the motion in the actuator. A Gradient Echo pulse sequence was modified using the Siemens IDEA environment for MRE application. A phantom was made with concentrations of 1%, 2%, and 3% agar gel.</p> <p>The phantom was scanned using the MRE sequence while inducing the propagating waves. Waves were selected to have frequencies of 125 Hz and 250 Hz. Magnitude and phase images acquired at these frequencies were used to construct the elasticity map using the MRE/Wave reconstruction software. Mean Shear Modulus measured in 1% gel cylinder is 10 kPa and standard deviation (SD) is 6 kPa. Mean elasticity value measured in 3% gel is 49 kPa and SD is 9 kPa. Mean value measured in the background which is 2% gel is 28 kPa and SD is 6 kPa. The results obtained are comparable to the values calculated in literature.</p>en_US
dc.subjectMREen_US
dc.subjectElastographyen_US
dc.subjectElasticityen_US
dc.subjectBiomedical Engineering and Bioengineeringen_US
dc.subjectBiomedical Engineering and Bioengineeringen_US
dc.titleMagnetic Resonance Elastographyen_US
dc.typethesisen_US
dc.contributor.departmentBiomedical Engineeringen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
8.22 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue